T-Power Shoe

The innovative third generation GJS hydraulic system GEN3.X was created by Powell to increase the commercial speed of well construction by running casing strings without preliminary preparation and cleaning of the wellbore.

Profits & benefits

Powered drilling solution for complicated wells with reinforced worked section.

0 %

Accident rate during well cementing and drilling

Amet minim mollit non deserunt ullamco est sit aliqua dolo.

70 %

Increasing the effectiveness of descents

Amet minim mollit non deserunt ullamco est sit aliqua dolo.

1 hours

Reamer shoe drilling time

Amet minim mollit non deserunt ullamco est sit aliqua dolo.

About

Powered drilling solution for complicated wells with reinforced worked section.

The main engineering challenge was a significant increase in the shoe rotation speed of more than 3500 rpm to reduce the working displacement while maintaining power and reducing the time for working out complications during running the casing string, as well as the resistance of the power section to the abrasive effect of the drilling fluid.

Instant start of rotation when circulating flow makes it possible to start development at low displacement without the risk of lost circulation or hydraulic fracturing at an increased flow rate
Significant increase in power to reduce turnaround time
Increase in the shoe life due to the special coating of the elements of the power section.
Gallery

Specifications

Key differences
for GJS*
400
450
500
550
663
700
763
963
1075
1275
1338
Casing Size, in
Casing Size, mm
4.81
122.2
5.87
149.2
5.87
149.2
5.87
149.2
8.25
209.6
8.25
209.6
9.19
233.3
11.31
287.3
12.13
308.0
14.96
380.0
17.25
438.2
Blade OD, in
Blade OD, mm
4.81
122.2
5.87
149.2
5.87
149.2
5.87
149.2
8.25
209.6
8.25
209.6
9.19
233.3
11.31
287.3
12.13
308.0
14.96
380.0
17.25
438.2
Length, ft
Length, m
3.28
1.00
3.12
0.95
3.12
0.95
3.18
0.97
3.18
0.97
3.18
0.97
3.28
1.00
3.38
1.03
3.44
1.05
3.18
0.97
3.61
1.10
Tool mass, ibf
Tool mass, ibf
64
29
137
62
152
69
172
78
216
98
216
98
267
121
364
165
397
180
701
318
756
343
Flow Rate, gpm
Flow Rate, ips
30-190
2-12
30-240
2-15
30-240
2-15
50-320
3-20
50-400
3-25
50-400
3-25
80-560
5-35
160-700
10-45
160-700
10-45
190-1200
12-75
190-1200
12-75
Pressure Drop, psi
Pressure Drop, kPa
290
2000
300
2100
300
2100
330
2300
430
3000
430
3000
520
3600
680
4700
710
4900
800
5500
830
5700
Rotations per minute,
rpm
1330
1860
1900
2200
3000
3000
2910
2350
2440
2600
2550
Torque, ft.lbs
Torque, N.m
650
880
590
800
620
840
890
1200
1330
1800
1330
1800
1540
2080
1880
2550
2030
2760
2800
3800
2910
3950
Power, hp
Power, kW
130
100
170
130
180
140
300
230
580
430
580
430
630
460
630
460
680
500
890
650
900
660
Axial Load, klbs
Axial Load, t
90
40
90
40
90
40
90
40
90
40
90
40
90
40
90
40
110
50
110
50
110
50

* Data shown is for water as flushing fluid at a flow rate of 25 liters / second

General features

Powered drilling solution for complicated wells with reinforced worked section.

Drilling out with RSS or PDM for 15-30 minutes
Working loads over 40 tons
Free orientation in the wellbore
Working out during circulation
Does not create a pressure surge during an abrupt stop
Manufacturing of any standard size to order
Application ares
Play Video
CASING RUNNING

Running casing strings immediately after drilling a section without reaming the wellbore

COMPLICATED WELLS

Overcoming sludge cushions, clay swelling intervals, caverns and ledges

Functionality & configurations
GJS178B-3-1

Rotation

Rotation of both the shoe as a whole and separately only the front part

GJS178B-3-0

Sharp side

Sharp side of both the shoe as a whole and separately only the front part

GJS178B

Front design

Front design as a whole and separately only the front part

FAQ

Frequently asked questions

The rate of descent in the cased hole was 0.5 m / s, in the open hole – up to 0.3 m / s. When undermining a column of wedges after construction, before the start of circulation and walking, the drying speed per vira sometimes exceeded 0.2 m / s, which is unsafe from the point of view of the digital signature and could lead to collapses in the trunk.

Lorem Ipsum is simply dummy text of the printing and typesetting industry. Lorem Ipsum has been the industry’s standard dummy text ever since the 1500s, when an unknown printer took a galley of type and scrambled it to make a type specimen book. It has survived not only five centuries, but also the leap into electronic typesetting, remaining essentially unchanged. It was popularised in the 1960s with the release of Letraset sheets containing Lorem Ipsum passages, and more recently with desktop publishing software like Aldus PageMaker including versions of Lorem Ipsum.

Lorem Ipsum is simply dummy text of the printing and typesetting industry. Lorem Ipsum has been the industry’s standard dummy text ever since the 1500s, when an unknown printer took a galley of type and scrambled it to make a type specimen book. It has survived not only five centuries, but also the leap into electronic typesetting, remaining essentially unchanged. It was popularised in the 1960s with the release of Letraset sheets containing Lorem Ipsum passages, and more recently with desktop publishing software like Aldus PageMaker including versions of Lorem Ipsum.

Lorem Ipsum is simply dummy text of the printing and typesetting industry. Lorem Ipsum has been the industry’s standard dummy text ever since the 1500s, when an unknown printer took a galley of type and scrambled it to make a type specimen book. It has survived not only five centuries, but also the leap into electronic typesetting, remaining essentially unchanged. It was popularised in the 1960s with the release of Letraset sheets containing Lorem Ipsum passages, and more recently with desktop publishing software like Aldus PageMaker including versions of Lorem Ipsum.

News & updates

Related case studies

Case study Pihtovoye 3G - GJS

Amet minim mollit non deserunt ullamco est sit aliqua dolo. Amet minim mollit non deserunt ullamco est sit aliqua dolo.

Case study Pihtovoye 3G - GJS 2

Amet minim mollit non deserunt ullamco est sit aliqua dolo. Amet minim mollit non deserunt ullamco est sit aliqua dolo.

Case study Pihtovoye 3G - GJS 1

Amet minim mollit non deserunt ullamco est sit aliqua dolo. Amet minim mollit non deserunt ullamco est sit aliqua dolo.

Get in touch with our expert

Please fill in your contact information and our expert will contact you soon

Thank you for contacting us, our expert will contact you soon

Please fill in your contact information and our expert will contact you soon